Service instructions for JA-110A
BUS internal siren
This product is a part of the JABLOTRON JA-100 alarm system. It provides the display of an alarm indoors. Other sound indications are also possible. Pressing the siren extinguishes the alarm or calls the emergency alarm (functionality can be set). The siren is intended to be installed by a trained technician with valid Jablotron certification.
Installation
The siren can be mounted directly on the wall or on an appliance installation box (without the lower part plastic).
1. Remove the body of the siren from the frame - by prying into the vertical gap with a screwdriver (1.).
2. By pressing on the clips (2.) remove the frame piece (3.).
3. Select a suitable passage and pass the bus cable through.
4. Screw the plastic backing to the selected location.
Before connecting the BUS, the system must be disconnected from the power supply.
5. Connect bus cable.
6. Complete configuration of the siren. Note that the tamper sensor (7) must be above the magnet in lower plastic. If the siren is mounted on the installation box (without lower part plastic), move the magnet in the frame of the siren.
7. Continue to follow the instructions for installation of the control center. Basic steps:
a. After power on, the yellow signal light (1) flashes because the siren is not assigned to the system.
b. In the F-Link program on the Peripheral Devices card, select the desired position and start the learning mode with the Read button.
8. Press the siren (up or down) - causing it to learn and the yellow light will extinguish.
Figure: 1 - signal light; 2 - keys inside; 3 - serial number; 4 - pins of push buttons; 5 - piezo siren; 6 - terminals for the bus; 7 - sabotage sensor;
Setting the properties
This is done by the F-Link program - card Peripheral devices. On position of the siren Use Internal setting. A dialog appears, allowing settings to be made (* indicates factory setting)
Section: this determines for which sections the siren will operate and possibly also signal entry/exit delay and reinforcement. From the factory, the sound signal is set for all sections.*
Reaction: this determines, whether the siren will sound on signal IW* (warning inside) or EW (warning outside). The alarm sound can also be switched off completely (other functions are retained).
Siren sound: with interruption*, without interruption
Duration limitation for mooing: 1, 2, 3*,4, 5 minutes.
Louder sound: YES / NO* - this only affects signaling of entry/exit delay and the sounds on contact of PG outputs.
Beep sound when operating sections: YES / NO* - if enabled, the siren beeps 1x on rearming, 2x on disarming and 3x on disarming after an alarm. Only for set sections.
Beep at walk-in and walk-out delay: YES / NO* if enabled, signals the walk-out and walk-in delay of the set sections.
Sound of PG outputs:
A sound signal can be set for each PG output:
Sound 1 - slow beeping 1 x per second (as long as the PG is on)
Sound 2 - fast beeping 2 x per second (as long as the PG is on)
Sound 3 - 1x beep when turning on the PG, 2 x when turning off PG
Sound 4 - long beep for 20 sec when PG is turned on
Priorities of siren operation:
The highest priority is the siren mooing, a lower priority is for the beeping at operation, the lowest is the activity of the PG outputs (PG1 higher than PG2, etc.). The higher priority sound always terminates the lower priority sound.
System response to siren pressing
From the factory it is set that when pressed during panic, the siren mutes the sound and also confirms that a human is present in the object (a report is sent). In the Peripheral Devices card of the F-Link program, you can change the function of the siren push button to emergency push button in the Response column. In this case, the system will respond with silent alarm in the section, in which the position of the siren is classified.
If the system is operating in service mode, one can test the function of the siren by long pressing.
Technical parameters
Power supply from central unit bus 12V (9...15 V)
Current consumption in standby (idle) 5 mA
Current consumption for cable selection 30 mA
Piezoelectric siren 90 dB/m
Dimensions 90 x 90 x 28 mm
Classification grade 2
In conformity with EN 50131-1, EN 50131-4
Environment in accordance with EN 50131-1 II. indoors, general
Operating temperature range -10 to +40 °C
Also complies with EN 50130-4, EN 55022, EN 60950-1
Product JA-110A is designed and manufactured in accordance with the provisions to be applied to it: Government Decree No. 17/2003 Sb. and 616/2006 Sb., if used according to its intended use. Original declaration of conformity can be found at www.jablotron.cz in the advice section
Remark: Although this product does not contain harmful materials, do not dispose of it in the domestic waste, but dispose of it at the collection point intended for electronic waste.