Service instructions for JA-110I
BUS section / output PG activation indicator
This product is a part of the JABLOTRON JA-100 alarm system. It provides an optical indication of the status of system sections (armed / disarmed) or the state of programmable outputs. The product is intended to be installed by a trained technician with valid Jablotron certification.
Installation
1. Open the indicator cover by loosening the four snap clips using a suitable flathead screwdriver, turning in the direction of arrows.
2. Loosen the snap clip (1) and remove the plate.
Illustration: 1 - click clamp of the plate; 2 - switch of the configuration; 3 - red signal light of the indicator; 4 - hole to be broken open; 5 - terminals of the BUS
3. Using the switch (2), set the number of the section requiring indication (see Tab. 1) or PG output (see Tab.2).
4. Pull the cable through the created opening (4) and attach the back panel of the indicator at the selected location.
5. Fold back the indicator plate and connect the bus cable to the terminals (5).
Before connecting the BUS, the system must be disconnected from the power supply.
If the indicator is located outside the room to be monitored, the supply must be separated from its BUS with a JA-110T bus isolator.
6. After turning on the system, test its operation.
7. Replace the indicator cover.
Tab. 1 Setting for indication of a section
Tab. 2 Setting for indication of a Pg output
Notes:
- Indicator does not occupy a position in the control panel (it is not classified in the system).
- With several connected modules with the same setting, they are going to give the same indication.
- Number of indicators is limited only by current draw from the central controller.
Picture: dimensions JA-110I indicator.
Technical parameters
Power supply from the BUS of the central unit 12 V (9 ...15 V)
Current consumption in standby mode (LED on / off) 6 mA / 3 mA
Current consumption for cable selection 6 mA
Dimensions 62 x 36 x 27 mm
Rating grade 2
In conformity with EN 50131-1, EN 50131-3
EN 50131-1 II. indoor environment, general
Operating temperature range -10 to + 40 °C
Also complies with EN 50130-4, CSN EN 55022
Product JA-110I is designed and manufactured in accordance with the provisions to be applied to it: Government Decree No. 17/2003 Sb. and 616/2006 Sb., if used according to its intended use. Original declaration of conformity can be found at www.jablotron.cz in the advice section.
Note: Although this product does not contain harmful materials, do not dispose of it in the domestic waste, but dispose of it at the collection point intended for electronic waste.