JA-111A base

Service instructions for JA-111A base

Wired outdoor siren

This product is a part of the JABLOTRON JA-100 alarm system. The siren provides a visible and audible alarm indication outdoors. Other additional sound indications are also possible. The siren contains a backup battery that takes over in case of power failure. The product is intended to be installed by a trained technician with valid Jablotron certification. The product should be installed by a trained technician with a valid Jablotron certificate.

Installation
The siren is mounted on a vertical wall, with the flash facing down. Avoid mounting near gutters and in places, where ice formation is imminent.
 

Figure: 1 - electro-acoustic transducer; 2 - second electro-acoustic transducer; 3 - NiCd battery; 4 - opening for cable supply; 5 - plate of electronics siren; 6 - liquid vial; 7 - holes for mounting siren on the wall; 8 - screw of siren cover; 9 - cable with clasp for securing cover of central unit (by pressing the drop-in clamp it can be easily disconnected)


Figure: 10 - terminals of the BUS; 11 - key for learning; 12 - sabotage sensors; 13 - serial number; 14 - high voltage transformer; 15 - very sharp shining signal lights of the flash; 16 - yellow signal light of malfunction; 17 - connection of battery; 18 - connection of electroacoustic transducer (attention, high voltage)

1. Open the outer cover of the siren (screw 8 down)
2. Pull the bus cable through hole 4 in the rear part of the siren
3. Screw the siren to the chosen location with mounting holes 7 (2 screws), for determining the precise vertical position of the siren, the integrated vial 6 can be used

Before connecting the BUS, the system must be disconnected from the power supply.

4. Connect the bus cable to the terminals (10).
5. Plug the spare battery into the connector (17).
6. Continue to follow the manual for installation of the control center. Basic steps:
a. After power on, the yellow signal light (16) flashes because the siren is not assigned to the system.
b. In the F-Link program on the Peripheral Devices card, select the desired position and start the learning mode with the Read button.
c. Press the push button in the siren (11) - making it learn and the yellow light will go out.
7. Reinstall the cover of the siren.
Setting properties
This is done by the F-Link program - peripheral devices card. On position of the siren Select Internal setting. A dialog appears, allowing settings to be made: (* indicates factory setting)
Section: this determines for which sections the siren will operate and possibly also signal entry/exit delay and reinforcement. From the factory, the sound signal is set for all sections.*
Reaction: this determines, whether the siren will sound on signal EW* (warning outside) or IW (warning inside). The alarm sound can also be switched off completely (other functions are retained).
Siren sound: with interruptions*, without interruptions
Duration limitation for mooing: 1, 2, 3*,4, 5 minutes.
Louder sound: YES / NO* - this only affects signaling of entry/exit delay and the sounds on contact of PG outputs.
Beep sound when operating sections: YES / NO* - if enabled, the siren beeps 1x on rearming, 2x on disarming and 3x on disarming after an alarm. Only for set sections.
Flashing 30 minutes after alarm: YES / NO* extended flashing (flashing) can be stopped by rearming the system or by clearing alarm indication in the system (from the keypad).
One flash every 60 seconds: YES / NO* optional indication of operation.

Sound of PG outputs:
A sound signal can be set for each PG output:
Sound 1 - slow beeping 1 x per second (as long as the PG is on)
Sound 2 - rapid beeping 2 times per second (as long as the PG is on)
Sound 3 - 1x beep when turning on the PG, 2 x when turning off PG
Sound 4 - long beep for 20 sec when PG is turned on

Priorities of siren operation:
The highest priority is the siren mooing, a lower priority is for the beeping at operation, the lowest is the activity of the PG outputs (PG1 higher than PG2, etc.). The higher priority sound always terminates the lower priority sound.
Connection to the control center is disconnected
If the supply cable is disconnected, the siren will moo and flash for 3 minutes (this does not happen when the system is in service).
Technical parameters
Power supply from the BUS of the central unit 12 V (9...15 V)
Current consumption in standby (idle) 5 mA
Current consumption for cable selection 50 mA
Backup battery NiCd pack 4.8 V / 1800 mAh
service life approx 3 roky
Piezoelectric siren 110 dB/m (with fully charged battery)
Dimensions 200 x 300 x 70 mm
Classification grade 2
According to CSN EN 50131-1, CSN EN 50131-4
Ambient class IV outdoors, general -25 to +60°C
Degree of protection IP34D
Also complies with CSN EN 50130-4, CSN EN 55022, CSN EN 60950-1

Product JA-111A is designed and manufactured in accordance with the provisions to be applied to it: Government Decree No. 17/2003 Sb. and 616/2006 Sb., if used according to its intended use. Original declaration of conformity can be found at www.jablotron.cz in the advice section.

Remark: Although this product does not contain harmful materials, do not dispose of it in the domestic waste, but dispose of it at the collection point intended for electronic waste. 

No products