1 Installation

Installation of Oasis components is reserved only for and distributor-certified installers. The control panel is designed for indoor use, especially for the main entrance door of an object.
1. Open the control panel housing by pressing the TAB at the bottom with a screwdriver.
2. Install the bottom plate in the desired location.
3. Connect the cable to the control panel. There are two options:
- Use a flat telephone cable with RJ connectors (max. 10 meters). There is a digital bus in the control panel and the control panel. (This is for temporary installation only).
- Use a braided cable 4 wire (max. 100mtr) - The corresponding marked contacts must be connected to each other. Via the cable wires (GND, A, B, +U)
4. Install the external door detector (if used ) and connect its wiring to the IN and GND terminals
5. Reconnect the control panel internal wiring back into place.
6. Control panel programming instructions can be found in the control panel installation manual

2 Setting the display status enable/disable

In accordance with the EN standard, the control panel will not display the status of the system being switched ON or OFF. The status can only be read during operation or an entrance delay. However, it is possible to have this indication on the display, but it will have to be programmed after consideration.

3 Installation of a door detector

It is possible to connect a wired detector to the control panel via the IN input. The IN input contact will be actuated when the GND is disconnected. The natural response from the control panel to the IN input will give an activated delay intrusion alarm. ( non-changeable response)

Remark:
· If the IN input is not used, connect it to GND.
- The IN input only reports the breaking of the magnetic contact to the control panel, (it does not indicate open door status).

4 Controlling the PgX output

The PgX output can be switched on and off by pressing and holding the Ü (on) and the # (off) for 5 seconds. The function of the PgX must be set via the control panel. A long tone confirms the setting.

5 Entering control panel text

It is recommended to use a PC with OLink software to input the text. If you change the text in the system using OLink the change will take place in all control panels. If you want to use a new control panel, you can synchronize your modified texts with the new control panel.
The names can be entered via the control panel in the ''Edit Text'' menu - for this see the installation manual of the control panel. The entered text is stored only in the control panel used for data entry.